On U-Line Echelon 2000 refrigerators with the 2010 control, such as the 2175RF and the CLRCO2175, E4 records that the compressor had 100 percent runtime between two defrost cycles. It does not show on the display.…
On U-Line Echelon 2000 refrigerators with the 2010 control, such as the 2175RF and the CLRCO2175, E4 records that the compressor had 100 percent runtime between two defrost cycles. It does not show on the display. It appears only in the error log, so you find it when a technician reads the log, not as a message on the panel.
1. Confirm the unit has ventilation space on every side it needs. 2. With the unit unplugged, brush or vacuum the front grille if it is dusty. 3. Check that the door and drawer seal all the way around. 4. Avoid loading a large amount of warm food at once. 5. If cooling stays weak, call us to read the log.
You will not see it on the display. E4 lives in the error log, which we read through the control's diagnostic mode. Seeing it there tells us the compressor never rested between defrosts.
No. It means the compressor ran nonstop between defrosts. The cause can be a dirty condenser, leaking door seals or a weak refrigeration system, so we test each in order.
Not before we read it. The log shows the history that points to the cause. After the repair we clear it so any new entry stands out.
A technician diagnoses it on site and gives you the price in writing before any work starts.