Most common issues on this model

  1. Very limited condenser air volume in a 14-inch cabinet
  2. Scale quickly affecting output on a small evaporator
  3. Bin filling faster than in wider models

At 14 inches, the ACR014 is the narrowest ice machine in the ADA range, and it slides into the slimmest accessible openings. It makes crescent ice in a harvest cycle, dropping the cubes into a bin that suits a small kitchen or a single-station break area.

Narrow means little room for air. The condenser has very little volume to draw from, so lint on the coil or a tight cutout raises temperature and slows production quickly. The evaporator is small too, which means scale affects output sooner than on a wide machine.

We vacuum the coil and measure clearances, then descale the evaporator and check the harvest cycle. The smaller bin fills fast, so we test the bin-full sensor as well. A written price comes first, and a 30-day warranty follows.

Key features

  • 14-inch ADA-height crescent ice maker
  • The narrowest ice machine in the ADA range
  • Accessible-height cabinet
  • Crescent harvest-cycle production
→Codes

Error codes this model can show

ACR014ACR014 questions
Why does a narrow ice maker lose output so fast?

Its condenser and evaporator are small, so dust or scale has a bigger effect than in a wide cabinet. We clean both surfaces and check the cutout clearances to restore full production.

The bin fills quickly and the machine stops. Is that normal?

A smaller bin does fill faster. If the machine stops while the bin still has room, the bin-full sensor is misreading, and we clean and test it with a hand in the bin.

How is crescent ice made in this machine?

Water freezes onto the evaporator, then a harvest cycle warms it briefly so the cubes release into the bin. We check each step when output drops, starting with scale on the evaporator.