U-Line Ice Machine Code E5 Shows a Shorted Thermistor 1

On U-Line ice machines such as the UONB115, UHNP315 and UCLR1215, E5 reports Thermistor 1 shorted. The first temperature sensor is delivering a signal the control reads as a direct short, so the value cannot be…

Medium · inspection needed
Code
E5
Appliance
Ice Machine
Brand
U-Line
Warranty
30-day workmanship

What E5 means

On U-Line ice machines such as the UONB115, UHNP315 and UCLR1215, E5 reports Thermistor 1 shorted. The first temperature sensor is delivering a signal the control reads as a direct short, so the value cannot be real. E5 appears on the display and ice production drops until the circuit is repaired. The matching open reading for this sensor is E1, and the display tells us which condition the control found.

Common causes of E5

  • Thermistor 1 has shorted internally
  • A sensor wire is pinched or damaged
  • Dampness or corrosion on the sensor plug
✓ One safe check you can try

1. Switch off the machine, wait one minute and turn it on again. 2. Check for water pooling near the cabinet. 3. Make sure the bin door is shut. 4. Do not open panels. 5. Call us if E5 returns.

! Why to stop there
  • A short is found by testing, not by sight
  • The sensor, the wire and the connector each call for a different fix
  • Pricing is given first and the work is warranted for 30 days
Opening a panel yourself does not automatically cancel a manufacturer warranty, but it can cause accidental damage, and some manufacturers set their own service conditions. Check your warranty terms, or ask us, before deciding.
→Same appliance

Other Ice Machine codes

E5E5 questions
What does E5 mean?

On E5 the first sensor is shorted, and the control reads the first sensor as a direct connection and cannot use the value for the ice cycle. A technician tests the circuit to find the short.

How does E5 differ from E1?

E1 is the same sensor reading open. E5 is the shorted reading, so the circuit failed in the opposite way, though both lead to the same sensor check.

Can moisture cause E5?

Dampness at a sensor connector produces a shorted reading, which is one reason we check the connector and the wire before replacing the sensor itself.