On U-Line ice machines such as the UONB115 and UHNP315, E3 means Thermistor 3 is open. The control has lost the signal from its third temperature sensor. Clear ice machines such as the UCLR1215 never show…
On U-Line ice machines such as the UONB115 and UHNP315, E3 means Thermistor 3 is open. The control has lost the signal from its third temperature sensor. Clear ice machines such as the UCLR1215 never show E3. The display shows E3, and the ice cycle runs without that reading until the circuit is repaired. E7 is the shorted version of this reading.
1. Switch the machine off, wait a minute and restore power. 2. Keep the area around the cabinet clear for airflow. 3. Check that the bin door closes fully. 4. Do not open panels. 5. Call us if E3 returns.
No. On the clear ice UCLR1215, E3, E4, E7 and E8 do not apply. Those codes belong to the other U-Line ice machines, such as the UONB115 and UHNP315.
E3 is Thermistor 3 open. The control gets no signal from that sensor, so the ice cycle loses one of its temperature readings. Testing the sensor path shows which part needs work.
Yes. E7 reports Thermistor 3 shorted, so E3 and E7 describe the same sensor in its two failure conditions, and both are checked the same way.
A technician diagnoses it on site and gives you the price in writing before any work starts.