U-Line Echelon 2000 refrigerators with the 2010 electronic control, including the 2175RF and the 2175DWRR, show E2 when thermistor 1 is shorted. The control reads the main temperature sensor as a direct short instead of a…
U-Line Echelon 2000 refrigerators with the 2010 electronic control, including the 2175RF and the 2175DWRR, show E2 when thermistor 1 is shorted. The control reads the main temperature sensor as a direct short instead of a normal, changing resistance, so it cannot trust the cabinet temperature. E2 appears on the display where the set point normally sits. This code is not available on the CLR2160.
1. Note the code and the time it appeared. 2. Unplug the refrigerator for one minute and restore power. 3. Check that the door closes fully and that food is not blocking the airflow. 4. If E2 comes back, check the food temperature and call us. Leave all panels closed.
E1 is an open thermistor 1 and E2 is a shorted thermistor 1. Both are circuit problems on the same sensor, but they point to different failures in the sensor or its wiring.
The control cannot read cabinet temperature correctly, so check with a separate thermometer. If it reads above 41 F, move perishables to another cooler until we repair the sensor.
A short comes from the sensor or pinched wiring rather than a loose plug, which tends to read open. We test the circuit with a meter to see which one you have.
A technician diagnoses it on site and gives you the price in writing before any work starts.