E4 appears on U-Line 1000 Series and 2000 Series wine coolers when Thermistor 4 is open. The fourth temperature sensor does not complete its circuit, so the control cannot read it. Older listings gave E4 a…
E4 appears on U-Line 1000 Series and 2000 Series wine coolers when Thermistor 4 is open. The fourth temperature sensor does not complete its circuit, so the control cannot read it. Older listings gave E4 a different meaning, but on these series it is a sensor reading. The 5 Class UHWC524 does not use E4.
1. Take power off for one minute and restore it. 2. Find the real temperature with a thermometer. 3. Clear moisture from behind the cabinet. 4. Leave all panels alone. 5. Call us if E4 returns.
The fourth temperature sensor circuit is incomplete, so Thermistor 4 reads open.
No. The 5 Class UHWC524 does not use E4, so the code applies to the 1000 and 2000 Series coolers.
Yes. E8 is the shorted reading for the same sensor, and E4 is the open reading.
A technician diagnoses it on site and gives you the price in writing before any work starts.